Disturbance recorder analysis

Turn grid disturbances into clear engineering evidence.

Wiztric centralises disturbance records, protection events and fault waveforms so engineering teams can investigate incidents, correlate equipment behaviour and produce consistent analysis.

Overview

From scattered fault files to a unified incident view.

Bring records from substations and protection devices into one controlled workspace for investigation, comparison and reporting.

01 / COLLECT

Record acquisition

Gather disturbance files, oscillography and protection events from supported devices and existing repositories.

  • Multi-site record collection
  • COMTRADE file handling
  • Device and source traceability
02 / ANALYSE

Fault investigation

Review aligned waveforms, digital states and event timing with the context needed for engineering analysis.

  • Signal overlay and comparison
  • Time-aligned event review
  • Trip and relay-operation correlation
03 / REPORT

Engineering evidence

Maintain a searchable incident history and produce consistent findings for review and follow-up.

  • Incident classification and notes
  • Standardised analysis reports
  • Investigation and action history

Core capabilities

Purpose-built for protection and disturbance investigation.

Centralise the records, tools and engineering context required to move from fault occurrence to defensible conclusions.

01

COMTRADE records

Store and organise supported configuration and waveform record sets.

02

Waveform viewer

Inspect analogue channels, digital states, timing and signal relationships.

03

Event alignment

Correlate relay, breaker and system events along a common incident timeline.

04

Fault calculations

Support engineering review with measurements, markers and calculated values.

05

Protection correlation

Compare recorded conditions with relay and breaker operation sequences.

06

Central archive

Search records by site, feeder, device, time, incident and classification.

07

Analysis reports

Generate consistent investigation summaries with evidence and findings.

08

Controlled access

Support role-based review, audit history and governed engineering workflows.

Designed for

Networks where fault evidence must be found quickly.

The platform supports focused protection teams or a central disturbance-analysis function spanning multiple substations.

  • Transmission and distribution utilities
  • Industrial power systems and captive networks
  • Protection, testing and commissioning teams
  • Substation and network control centres
  • Engineering incident-review functions

Connected foundation

Work with records from the protection environment.

Build a central engineering layer above supported relay, recorder and substation data sources.

  • Digital fault recorders and protection relays
  • COMTRADE disturbance record repositories
  • Sequence-of-events and trip information
  • Substation databases, historians and APIs
  • Asset, feeder and incident metadata
COMTRADEDFRSOEIEDReports

Analysis flow

From disturbance capture to engineering conclusion.

A consistent workflow makes evidence easier to find, compare, review and retain.

  1. 01

    Acquire

    Collect records and metadata from supported relays, recorders and repositories.

  2. 02

    Correlate

    Align waveforms, digital states, relay events and breaker operations.

  3. 03

    Analyse

    Review measurements, timing and protection behaviour with engineering context.

  4. 04

    Report

    Document findings, retain evidence and track investigation outcomes.

Start a conversation

Need centralised disturbance analysis across your network?

Tell us about your relays, recorders, COMTRADE files, substations and engineering investigation workflow.